The 54/2014. (XII.5.) BM decree the National Fire Protection Regulations (OTSZ) provides for the rules for the maintenance and operation of safety and escape lighting.According to the legislation, the so-called it is necessary to keep an operation and maintenance log. The maintenance log was prepared on the basis of the legislation.
Operator checks of safety lighting, externally or internally illuminated escape signs, and turn signal lighting according to previous regulations are due monthly and must be recorded in the fire protection operation log. Inspection and maintenance are due every 12 months, i.e. annually.
In case of stock shortage, production is continuous, and service is performed in the order of received orders. Typical production time is 2-3 weeks.
Content and composition of the log:
The diary is a spine-reinforced version, stapled prepare.
146. § (1) Safety lighting must be installeda) on the escape route of the KK and MK class building,b) on the escape route of a kindergarten, school, child welfare, child employment or forced stay institution,c) temporary in a protected space and on the route used for the firefighting units to access the premises,d) in the forecourt of the safety elevator,e) in the fire brigade intervention center and on the route used for the firefighting units to approach the premises,f) in case of fire in the room containing the main switch and on the route used for the firefighting units to access the room,g) in the room of the fire alarm center and on the route used for the firefighting units to access the room,h) in the room containing the shut-off assembly of the built-in firefighting equipment and the firefighter for units on the route used to approach the room,i) in a room for mass stay,j) where required by this regulation andk) * where required by the fire protection authority to ensure escape. (2) High-up or, if not possible, medium-high escape signs illuminated from the outside or inside must be installeda) on the escape route of the AK, KK and MK class building orb) in the room with a capacity of more than 100 people. (3) * (4) The lighting of the escape signs prescribed in paragraph (2) must be in continuous operation during the period of use in the part of the building where the fleeing persons do not have local knowledge.(5 ) Anti-panic lighting must be installeda) in rooms for mass stay andb) in rooms for accommodating persons who cannot be rescued or who can be rescued with preparation. must be installed as a supplement to high-mounted safety signs, wherea) this regulation orb) the fire protection authorityrequires based on the characteristics of escape and smoke development.
< br />All >> << can be purchased on site during our fire protection exam.